Search

The project is part of a broader initiative undertaken by the City of Łódź aimed at improving the management of stormwater and meltwater. The existing open tank at Liściasta Street no longer met the requirements regarding the volume of retained water or the quality of its treatment.

 

Effective stormwater treatment is essential due to runoff from the nearby residential area, which flows through the stormwater drainage system. Until now, partially treated water was discharged directly into the tank and the Sokołówka River, which runs through the area.

The installation of a new tank employing environmentally friendly technologies improves both retention efficiency and water treatment quality, benefitting the surrounding environment.

 

The total project cost amounted to PLN 5.1 million gross.

The project, titled “Nature Supported by Technology – A Retention Tank with a Hydrofit Pre-Treatment System at Liściasta Street in Łódź”, was implemented by Ecol-Unicon and received 1st Prize in the “Environmental Protection” category at the Smart City Poland Award 2024 competition.

 

 

 

Moreover, the project has been included on the map of good practices in Interreg Europe – a program co-funded by the European Union. Its aim is to facilitate the exchange of knowledge and experiences in sustainable and innovative solutions across Europe.

Scope of work

  • Design of the stormwater pre-treatment facility modernization
  • Demolition of existing pre-treatment structures
  • Construction of a retention tank with a total capacity of 900 m³
  • Construction of the hydrofit pre-treatment system
  • Installation of pre-treatment devices, including sedimentation tanks, separators, and tanks
  • Construction of process pipelines
  • Installation of control, automation, and water pre-treatment measurement systems
  • Construction of fencing, access roads, pedestrian pathways, and surface hardening for pre-treatment facility maintenance

How does the implemented solution work?

In the newly constructed facility in Łódź, we implemented the HYDROZONE BENEFIT retention tank, one of the most advanced solutions available. It enables not only water retention but also its reuse, achieved through pre-treatment devices and the operation of a hydrofit system with appropriately selected vegetation.

 

How does it work? The retention tank, with a total capacity of 900 m³, collects stormwater, which is pre-treated as it flows through a series of devices that remove suspended solids and floating contaminants. Hydrocarbon substances are eliminated using a lamella separator. Additionally, organic pollutants are filtered out in the hydrofit section, thanks to the planted vegetation and gravel layer. To keep the retained water fresh, aeration and flushing jets have been installed. These devices supply oxygen to the tank, preventing water stagnation and decomposition.

The retention tank installed by Ecol-Unicon is divided into three sections:

 

  1. Operational Section (0.5 m height, 150 m³ capacity) – The water collected here is reused for municipal purposes, such as street cleaning, channel flushing, green space irrigation, and sewer maintenance. Additionally, it supplies water to the hydrofit section during dry periods. In such cases, the water circulates in a closed loop, flowing through the filtration layer and back into the tank to ensure continuous plant irrigation.
  2. Working Section (1.5 m height, 450 m³ capacity) – This section retains incoming stormwater, which is subsequently pumped into the hydrofit system for treatment of organic pollutants.
  3. Emergency Section (1.0 m height, 300 m³ capacity) – This section provides overflow retention in case the working section reaches its capacity, for instance, during pump system failures.

Ecol-Unicon was also responsible for surface development around the pre-treatment facility. The area surrounding the tank and the Sokołówka River serves as a recreational space for the residents of Łódź, making the visual aspect of the project equally important.

 

The investment at Liściasta Street in Łódź demonstrates a comprehensive approach to stormwater retention. The project focuses not only on water storage but also on pre-treatment, enabling its reuse for municipal purposes and green space irrigation.

Such technological solutions reflect the latest global trends, which, in the face of climate change, aim not only to retain water but also to reuse it for other purposes.

 

An implementation on this scale is truly innovative and paves the way for future projects. It can be successfully applied in urban areas dominated by concrete surfaces and other sealed city squares, offering a much-needed introduction of greenery to such spaces.

 

The use of a prefabricated tank significantly shortened the installation time, allowing the project to be completed within the planned schedule. The project was carried out in a city park with limited available space, which required careful intervention in the existing tree stand. We selected construction methods that minimized tree felling to the necessary minimum. The earthworks were conducted in the Sokołówka River valley, where the groundwater level was high. Here, the use of concrete and the weight of prefabricated components proved advantageous, counteracting buoyant forces and facilitating assembly onto the foundation slab.

 

Przemysław Dębski, Service Department Director, Ecol-Unicon

Applied solutions

High-efficiency coalescence separator ESK 20

 

  • Total capacity – 20 dm3/h
  • Total weight – 3100 kg
  • Weight of the heaviest element -2300 kg
  • Oil storage volume – 480 dm3
  • Diameter of inlet/outlet DN – 200 mm
  • Diameter – 1200 mm

Applied solutions

Settling tank EOS 2000 x 1:

 

  • Active volume – 5 m3
  • Total weight – 10750 kg
  • Sediment layer thickness – 80 cm
  • Diameter of inlet/outlet DN – 1000 mm
  • Diameter – 2000 mm

High-efficiency coalescence separator ESK-BH II 6/60/1200/250:

 

  • Total capacity – 15 dm3/s
  • Total weight – 3400 kg
  • Weight of the heaviest element -3300 kg
  • Oil storage volume – 220 dm3
  • Diameter of inlet/outlet DN – 250 mm
  • Diameter – 1200 mm

High-efficiency coalescence separator ESK 15:

 

  • Total capacity – 15 dm3/s
  • Total weight – 2900 kg
  • Weight of the heaviest element -2200 kg
  • Oil storage volume – 480 dm3
  • Diameter of inlet/outlet DN – 200 mm
  • Diameter – 1200 mm

Applied solutions

Further success in Lithuania. Together with strategic partner Prespa, Ecol-Unicon was honored to supply a brand new rainwater treatment line for Boar Crossing between Lithuania and Belarus. Construction works should be ended within the next few months but three sets of settling tanks and high-efficiency separators are ready to serve with good faith and fidelity to protecting the environment.

Settling tank EOS 2000 x 3

High-efficiency coalescence separator ESK 100 x 2:

 

  • Total capacity – 100 dm3/h
  • Total weight – 8200 kg
  • Weight of the heaviest element – 6300 kg
  • Oil storage volume – 1900 dm3
  • Diameter of inlet/outlet DN – 315 mm
  • Diameter – 2000 mm

High-efficiency coalescence separator ESK 80 x 1:

 

  • Total capacity – 80 dm3/h
  • Total weight – 8200 kg
  • Weight of the heaviest element – 6300 kg
  • Oil storage volume – 1900 dm3
  • Diameter of inlet/outlet DN – 315 mm
  • Diameter – 2000 mm

Applied solutions

Delivery, assembly and start-up of two large double pre-treatment systems:

 

Lamella separator ESL-Z 560/5600 – 4 pcs.

 

  • separator chamber dimensions 6000 mm / 4500 mm,
  • nominal capacity of the system 560 l/s,
  • maximum capacity 5,600 l/s

Two-chamber vortex settling tanks EOW-2 – 4 pcs.

 

  • diameter of the first chamber: 6000 mm,
  • diameter of the second chamber 3000 mm,
  • nominal capacity of the system 560 l/s,
  • maximum capacity 5,600 l/s,
  • capacity of the sediment section 104 m3,
  • permissible height of the sediment layer 54 cm

Delivery, assembly and start-up of two small double pre-treatment systems:

 

Lamella separator ESL-Z 100/1000 – 2 pcs.

 

  • separator chamber dimension 2500 mm
  • nominal capacity of the system 100 l/s,
  • maximum capacity 1000 l/s,
  • actual capacity of the sedimentary part 790 dm3,
  • 1950 dm3 oil storage capacity.

Two-chamber vortex sedimentation tanks EOW-2 100/1000 – 2 pcs.

 

  • diameter of the first chamber 2500 mm,
  • diameter of the second chamber 1500 mm,
  • nominal capacity of the system 100 l/s,
  • maximum capacity 1000 l/s
  • capacity of the sediment area 8.7 m3,
  • permissible height of the sediment layer 52 cm,
  • single pre-treatment system EOW + ESL-Z 40/400

Overfill, oil level and sediment alarms with GSM modem have been installed in the systems. The whole is powered by 4 triple solar systems.

Project details

Works on the construction of the Bar-Boljare highway (169.2 km) officially started on May 11, 2015. The construction of the priority section Smokovac – Uvač – Mateševo ​​was planned for four years. According to official information, the contractor was to complete the construction of a 41-kilometer section with 45 bridges and flyovers and 32 tunnels within 48 months. More information about the project can be found here more.

Our partner from Bosnia and Herzegovina – manufacturer of concrete products BINIS, supplied for the aforementioned project approximately 30 coalescence separators with a nominal flow of 40 to 150 l/s using technological equipment from Ecol-Unicon, among various road construction products of their own production. We are very proud to cooperate with such a partner and to have an opportunity to use our products in such huge projects.

 

Scope of delivery: 30 coalescence separators (including separators with bypass), nominal flow from 40 to 150 l/s, manufacturer of the ESK and ESK-BII technological equipment for separators- Ecol-Unicon, manufacturer of concrete chambers – Binis, Bosnia and Herzegovina.

Within the next few weeks, the brand new settling tanks and separators will be installed and run into operation. Using our separators guarantees the highest treatment level thanks to the full compliance with the EN-858 norm. Ecol-Unicon first-class separators will ensure at least 5 mg/l at the outlet even for extremely high flows.

We are pleased to supply the highest quality equipment together with Byggros. It more than just about the environment, clean water is our common future. This is our way to make this World a better place.

Applied solutions

FC055SFR – Horizontal settling tank EOS 2500/10

Internal diameter Dw [mm]= 2500
Active capacity Vcz [m3]= 10
Concrete class: XC4, XA1, XF1, XD3, XS3

 

 

FC0001OUR – High efficiency lamella separator with cover at outflow section – ESL-Z 60/600

Chamber DN 2000
Nominal flow (NS) [dm3/s]= 60
Maximal flow [dm3/s]= 600
Oil storage volume [dm3]= 1200
Sedimentary section storage volume [dm3]= 550
Concrete class: XC4, XA1, XF1, XD3, XS3

FC00616R Sample well

Chamber with internal diameter Dw [mm]= 1200

 

FC051SFR – Horizontal settling tank EOS 3000/16

Internal diameter Dw [mm]= 3000
Active capacity Vcz [m3]= 16
Concrete class: XC4, XA1, XF1, XD3, XS3

 

FC015OUR – High efficiency lamella separator with cover at outflow section – ESL-Z 90/900 S

Chamber DN 2500
Nominal flow (NS) [dm3/s]= 60
Maximal flow [dm3/s]= 600
Oil storage volume [dm3]= 1950
Sedimentary section storage volume [dm3]= 790
Concrete class: XC4, XA1, XF1, XD3, XS3

 

FC0332R – Sample well

Chamber with internal diameter Dw [mm]= 1200
Concrete class: XC4, XA1, XF1, XD3, XS3