Search

Applied solutions

ESS-PE

 

Dry well pumping stations with a 2-pump system with a capacity of up to 200 m3/h. The capacity of the pumping station 14-33 l/s.

 

Retention module with dimensions:

 

  • module diameter = 2.60m
  • module height = 1.63m

The pumping station is equipped with:

 

  • Chamber – made of HDPE. There is a hole in the cover equipped with a cast iron manhole cover
  • Retention module – entirely made of HDPE. There are inspection hatches in the upper part of the module, enabling interior inspection, service, cleaning, while the pumping station is in operation.
  • Inlet and outlet piping with a diameter of 100 mm
  • 2-channel solids separators are located inside the retention module
  • Pneumatic system consisting of a compressor, air preparation station and pneumatic valves
  • Pumps (2 pieces) – mounted vertically outside the retention module. Pump protection degree IP 68. Pump operation – alternating.

Applied solutions

Dry well pumping station with a 3-pump system 
with a capacity of  Q = 310 m3/h.

Retention module with dimensions:

 

  • module diameter = 2.80m
  • module height = 3.20m

The pumping station is equipped with, among others in:

 

  • inlet-pressure piping with a diameter of 250mm
  • 2-channel solids separators are located outside the retention module (3 pieces)
  • a pneumatic system consisting of a compressor, air preparation station and 3 pneumatic valves with a diameter of DN200

The pumping station was installed in the DZB tank with the following parameters:

 

  • internal diameter: 5.50m
  • height = 7.25m